Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bioengineering (Basel) ; 11(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38391633

RESUMO

Cardiovascular diseases are a leading global cause of mortality. The current standard diagnostic methods, such as imaging and invasive procedures, are relatively expensive and partly connected with risks to the patient. Bioimpedance measurements hold the promise to offer rapid, safe, and low-cost alternative diagnostic methods. In the realm of cardiovascular diseases, bioimpedance methods rely on the changing electrical conductivity of blood, which depends on the local hemodynamics. However, the exact dependence of blood conductivity on the hemodynamic parameters is not yet fully understood, and the existing models for this dependence are limited to rather academic flow fields in straight pipes or channels. In this work, we suggest two closely connected anisotropic electrical conductivity models for blood in general three-dimensional flows, which consider the orientation and alignment of red blood cells (RBCs) in shear flows. In shear flows, RBCs adopt preferred orientations through a rotation of their membrane known as tank-treading motion. The two models are built on two different assumptions as to which hemodynamic characteristic determines the preferred orientation. The models are evaluated in two example simulations of blood flow. In a straight rigid vessel, the models coincide and are in accordance with experimental observations. In a simplified aorta geometry, the models yield different results. These differences are analyzed quantitatively, but a validation of the models with experiments is yet outstanding.

2.
Biomech Model Mechanobiol ; 22(3): 885-904, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36630014

RESUMO

Type B aortic dissection (TBAD) carries a high risk of complications, particularly with a partially thrombosed or patent false lumen (FL). Therefore, uncovering the risk factors leading to FL thrombosis is crucial to identify high-risk patients. Although studies have shown that morphological parameters of the dissected aorta are related to FL thrombosis, often conflicting results have been reported. We show that recent models of thrombus evolution in combination with sensitivity analysis methods can provide valuable insights into how combinations of morphological parameters affect the prospect of FL thrombosis. Based on clinical data, an idealized geometry of a TBAD is generated and parameterized. After implementing the thrombus model in computational fluid dynamics simulations, a global sensitivity analysis for selected morphological parameters is performed. We then introduce dimensionless morphological parameters to scale the results to individual patients. The sensitivity analysis demonstrates that the most sensitive parameters influencing FL thrombosis are the FL diameter and the size and location of intimal tears. A higher risk of partial thrombosis is observed when the FL diameter is larger than the true lumen diameter. Reducing the ratio of the distal to proximal tear size increases the risk of FL patency. In summary, these parameters play a dominant role in classifying morphologies into patent, partially thrombosed, and fully thrombosed FL. In this study, we point out the predictive role of morphological parameters for FL thrombosis in TBAD and show that the results are in good agreement with available clinical studies.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Trombose , Humanos , Aorta , Fatores de Risco , Resultado do Tratamento
3.
Int J Numer Method Biomed Eng ; 39(2): e3669, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36507557

RESUMO

Aortic dissection is caused by a tear on the aortic wall that allows blood to flow through the wall layers. Usually, this tear involves the intimal and partly the medial layer of the aortic wall. As a result, a new false lumen develops besides the original aorta, denoted then as the true lumen. The local hemodynamic conditions such as flow disturbances, recirculations and low wall shear stress may cause thrombus formation and growth in the false lumen. Since the false lumen status is a significant predictor for late-dissection-related deaths, it is of great importance in the medical management of patients with aortic dissection. The hemodynamic changes in the aorta also alter the electrical conductivity of blood. Since the blood is much more conductive than other tissues in the body, such changes can be identified with non-invasive methods such as impedance cardiography. Therefore, in this study, the capability of impedance cardiography in monitoring thrombosis in the false lumen is studied by multiphysics simulations to assist clinicians in the medical management of patients under treatment. To tackle this problem, a 3D computational fluid dynamics simulation has been set up to model thrombosis in the false lumen and its impact on the blood flow-induced conductivity changes. The electrical conductivity changes of blood have been assigned as material properties of the blood-filled aorta in a 3D finite element electric simulation model to investigate the impact of conductivity changes on the measured impedance from the body's surface. The results show remarkable changes in the electrical conductivity distribution in the measurement region due to thrombosis in the false lumen, which significantly impacts the morphology of the impedance cardiogram. Thus, frequent monitoring of impedance cardiography signals may allow tracking the thrombus formation and growth in the false lumen.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma Aórtico , Dissecção Aórtica , Procedimentos Endovasculares , Trombose , Humanos , Aneurisma Aórtico/complicações , Cardiografia de Impedância/efeitos adversos , Aorta
4.
Front Bioeng Biotechnol ; 10: 1033450, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36394040

RESUMO

Background: Type B aortic dissection (TBAD) is a dangerous pathological condition with a high mortality rate. TBAD is initiated by an intimal tear that allows blood to flow between the aortic wall layers, causing them to separate. As a result, alongside the original aorta (true lumen), a false lumen (FL) develops. TBAD compromises the whole cardiovascular system, in the worst case resulting in complete aortic rupture. Clinical studies have shown that dilation and rupture of the FL are related to the failure of the FL to thrombose. Complete FL thrombosis has been found to improve the clinical outcomes of patients with chronic TBAD and is the desired outcome of any treatment. Partial FL thrombosis has been associated with late dissection-related deaths and the requirement for re-intervention, thus the level of FL thrombosis is dominant in classifying the risk of TBAD patients. Therefore, it is important to investigate and understand under which conditions complete thrombosis of the FL occurs. Method: Local FL hemodynamics play an essential role in thrombus formation and growth. In this study, we developed a simplified phenomenological model to predict FL thrombosis in TBAD under physiological flow conditions. Based on an existing shear-driven thrombosis model, a comprehensive model reduction study was performed to improve computational efficiency. The reduced model has been implemented in Ansys CFX and applied to a TBAD case following thoracic endovascular aortic repair (TEVAR) to test the model. Predicted thrombus formation based on post-TEVAR geometry at 1-month was compared to actual thrombus formation observed on a 3-year follow-up CT scan. Results: The predicted FL status is in excellent agreement with the 3-year follow-up scan, both in terms of thrombus location and total volume, thus validating the new model. The computational cost of the new model is significantly lower than the previous thrombus model, with an approximate 65% reduction in computational time. Such improvement means the new model is a significant step towards clinical applicability. Conclusion: The thrombosis model developed in this study is accurate and efficient at predicting FL thrombosis based on patient-specific data, and may assist clinicians in choosing individualized treatments in the future.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...